TEND
รีเลย์และลิมิตสวิตช์ต่างๆ
 Limit Swich : TZ-7series 
SPECIFICATIONS
- high precision and long life (10,000,000 mechanicaloperations)
 - Sealed with gasket diaphragm to provide high sealing property without use of any adhesive or pin
 
| 
 Operating speed  | 
 0.01mm to 50cm/sec ( at pin plunger)  | 
| 
 Operating frequency  | 
 120 operations/min  | 
| 
 Contact resistance  | 
 15mΩ max.( initial)  | 
| 
 Insulation resistance  | 
 100MΩ max.( at 500 VDC)  | 
| 
 Dielectric strength  | 
 1,000VAC,50/60Hz, fo 1minute between non-continuous terminals 1,500VAC,50/60Hz, for 1 1minute between current-carrying and non-current-carring pasts and between each terminal and ground  | 
| 
 Vibration  | 
 Mechanical durability:10 to 55HZ, 1.5mm double amplitude  | 
| 
 Shock  | 
 Mechanical durability:1,000m/S²(approx.100G's)malfunction: 300m/S²(approx.30G's)  | 
| 
 Ambient temperature  | 
 Operating:-10 to +80ºC  | 
| 
 Humidity  | 
 95% HR max. ( at+20 to+35ºC)  | 
| 
 Service life  | 
 Mechanically:10,000,000 operations min. (At rated ot value)Electrically:500,000 operations min  | 
| 
 weight  | 
 Approx.60g  | 
| 
 Degree of protection  | 
 IEC:IP65  | 
SPECIFICATIONS
- RATINGS
 

OTES : 1.inductive load: powerfactor=0.4;
time constant =7msec.
2.Iamp load has an inrush current of 10 time the steady-state current while motor load has an inrush current of 6 times the steady-sate current.
CONTACT CONFIGURATION

OPERATION CHARACTERISTICS

- DIMENSIONS
 