เซนเซอร์แปลงความดัน Pressure Transmitter
รุ่น SMX2
คุณลักษณะ
The SMX2 can be configured in both zone 0 and zone 1 and meets the requirements of Directive IBExU 10 Atex 1014. Appropriate protective circuits guarantee inverse-polarity protection,overvoltage resistance and limitation of capacity loss in the event of any failure. Itswidely ranging industrial applications are guaranteed by its high precision and robustand compact design. A wide range of pressure transducers is on offer with the possibility of combining various mechanical and electrical connections. zone 0 An area where an explosive atmosphere of a mix of air and combustible gases, vapours or sprays is permanently, over long periods or frequently prevails. zone 1 An area where an explosive atmosphere of a mix of combustible materials in the form of gas, vapour or spray with air occurs occasionally in normal operation. Safety Note: When fitting, commissioning and operating this pressure transmitter, please observe relevant national safety regulations by all means.
- Measuring ranges 0…10 mbar to 0…2000 bar
- Explosion-proof certificate for zone 0 II 1G Ex ia IIB T4 Ga or II 1G Ex ia IIC T4 Ga
- Explosion-proof certificate for zone 1 II 2G Ex ia IIC T4 Gb
- Output signal 4…20 mA
- Highly reliable
- Digital version: ZERO function, down scale 4:1
| Pressure Range | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Measuring range* silicon technology | p [mbar] | 10 | 16 | 20 | 25 | 40 | |||
| - Overload pressure | p [mbar] | 50 | 80 | 100 | 125 | 200 | |||
| - Burst pressure | p [mbar] | 100 | 160 | 200 | 250 | 400 | |||
| Measuring range* stainlees steel diaphragm | p [mbar] | 60 | 100 | 160 | 200 | 250 | 400 | 600 | |
| - Overload pressure | p [mbar] | 120 | 200 | 360 | 400 | 500 | 800 | 1200 | |
| - Burst pressure | p [mbar] | 180 | 300 | 480 | 600 | 750 | 1200 | 1800 | |
| Measuring range* stainless steel diaphragm | p [bar] | 1,0 | 1,6 | 2,0 | 2,5 | 4,0 | 6,0 | 10,0 | |
| - Overload pressure | p [bar] | 6 | 6 | 6 | 6 | 10 | 20 | 20 | |
| - Burst pressure | p [bar] | 9 | 9 | 9 | 9 | 15 | 30 | 30 | |
| Measuring range* stainless steel diaphragm | p [bar] | 16 | 20 | 25 | 40 | 60 | 100 | 160 | |
| - Overload pressure | p [bar] | 40 | 40 | 100 | 100 | 200 | 200 | 400 | |
| - Burst pressure | p [bar] | 60 | 60 | 150 | 150 | 300 | 300 | 600 | |
| Measuring range* stainless steel diaphragm | p [bar] | 200 | 250 | 400 | 600 | 1000 | 1600 | 2000 | |
| - Overload pressure | p [bar] | 400 | 750 | 750 | 840 | 1200 | 2400 | 2400 | |
| - Burst pressure | p [bar] | 600 | 1000 | 1000 | 1050 | 1500 | 3000 | 3000 | |
| (Vacuum, relative pressure, +- or abso;ute pressure are available), Please note:> 1000 bar with thread M18x1,5 | |||||||||
| ELECTRICAL PARAMETER | |||||||||
| 2-wire | |||||||||
| Output signal* | 4...20mA | ||||||||
| Supply voltage | US [VDC] | 20...27 | |||||||
| Load resistor | RA [Ω] | acc. to RA =< (US-20V)/0,02 A | |||||||
| Responde time | t [ms] | ≥ 4 (digital) | ≥ 1 (Analog) | ||||||
| Maximum supply current | I [mA] | 23mA | |||||||
| Isolation voltage | U [VDC] | 500V AC | |||||||
| ACCURACY | |||||||||
| pressure range 1 bar to 2000 bar | pressure range 10 bar to 600 mbar | ||||||||
| Accuracy @ RT | % of the range | ≤0,50** | Option 0,25 | ≤1,00** | option ≤0,5 | ||||
| Non-lineearity | BFSL | ≤0,15 | ** incl. nonlinearity, hysteresis, repeatability, zero-offset- and final-offset (acc. to IEC 61298-2) | ||||||
| Stability/year | % of the range | ≤0,15 | |||||||
| ACCEPTABLE TEMPERATURE RANGES | |||||||||
| zone 0 | zone 1 | ||||||||
| Measuring medium | T [℃] | -20...60 | -40...100 | ||||||
| Ambience | T [℃] | -20...60 | -40...85 | ||||||
| Stroage | T [℃] | -40...120 | -40...120 | ||||||
| Compensated range* | T [℃] | -20...60 | -20...85 | ||||||
| Mean TC offset | % of the range | ≤ 0,15 / 10K | ≤ 0,15 / 10K | ||||||
| Mean TC range | % of the range | ≤ 0,15 / 10K | ≤ 0,15 / 10K | ||||||
| Total | % of the range | -20°C 1,00% | digits : -40°C 1,00% | Analog : -40°C 2,00% | |||||
| % of the range | 60°C 1,00% | digits : 85°C 1,00% | Analog : 85°C 2,00% | ||||||
| Directive ATEX | |||||||||
| zone 0 | zone 1 | ***cabel output max. 3 m (at longer than 3 m = level probe) |
|||||||
| Type of ignition protection | II 1G Ex ia IIB T4 Ga | II 2G Ex ia IIC T4 Gb | |||||||
| Type of ignition protection | II 1G Ex ia IIC T4 Ga (for connector M12x1 only) | ||||||||
| Underlying standards | EN 60079-0, EN 60079-11, EN 60079-26, EN 60079-14 (both zones) | ||||||||
| Maximum connected power | 27 V, 125mA, 0,85 W | 27 V, 125mA, 0,85 W | |||||||
| Temperature class | T4 (Ambience -20…+60° C) | T4 (Ambience -40…+85° C) | |||||||
| MECHANICAL PARAMETER | |||||||||
| Parts in contact with the measuring medium* | staniless steel | for pressure range of 1 bar 2000 bar | |||||||
| Parts in contact with the measuring medium* silicon | silicon | for pressure range of 10 bar 600 bar | |||||||
| Housing | Stainless steel | ||||||||
| Shock resistance | g | 1000 | acc. to DIN EN 60068-2-32-free fall | ||||||
| Vibration resistance | g | 20 | acc. to DIN EN 60068-2-6-vibration sinusoidal | ||||||
| G-Force | g | 50 | acc. to DIN EN 60068-2-27-shock | ||||||
| Mass | m [g] | ~150 | depending on design | ||||||
| Approval | IBExU10ATEX1014 | ||||||||
| IP system of protection (IEC 605029) up to IP69K | The IP system of protection as specified in the data sheets generally applies, with appropriate mating plug connected. | ||||||||
| * cumstomer specific configurations available | |||||||||