The SKL is a high-temperature pressure transducer with a cooling section. It can be used with liquid and gaseous media in temperatures of up to 180°C. These media are cooled down before measuring by means of cooling ribs that have been placed outside the sensor. This makes the SKL fit for use in heating systems, automotive equipment and in the chemical industry as well as for hydraulic and pneumatic applications involving higher temperatures.
The SKL has a stainless-steel chip with a semi-conductor thin film has been installed inside the SKL. The stainless-steel membrane is absolutely vacuumtight and extremely burst-proof. Its robust design guarantees to be highly reliable even in very rugged environments. Its modular design offers a multitude of signaling, threading and connecting options. Further0is available on request.
- Measuring ranges -1 bar to 5000 bar
- All standard signals for industry, hydraulics and pneumatics
- Media temperature range – 40°C to 180°C, optional to +200°C
- Ambient temperature range -40°C to 105°C
- Shock and vibration-resistant > 1000 g shock, > 20 g vibration
- No internal transmitting media (fully welded, “dry” measuring cell)
- Degree of protection from IP65 (special version up to IP69K)
- Compact and robust stainless steel design
- Precision class 0.5 %
PRESSURE RANGE | |||||||||
---|---|---|---|---|---|---|---|---|---|
Measuring range* | p [bar] | 1,0 | 1,6 | 2,0 | 2,5 | 4,0 | 6,0 | 10,0 | 16,0 |
- Overlaod pressure | p [bar] | 6 | 6 | 6 | 6 | 10 | 20 | 20 | 40 |
- Burst pressure | p [bar] | 9 | 9 | 9 | 9 | 15 | 30 | 30 | 60 |
Measuring range* | p [bar] | 20 | 25 | 40 | 60 | 100 | 160 | 200 | 250 |
- Overload pressure | p [bar] | 40 | 100 | 100 | 200 | 200 | 400 | 400 | 750 |
- Burst pressure | p [bar] | 60 | 150 | 150 | 300 | 300 | 600 | 600 | 1000 |
Measuring range* | p [bar] | 400 | 600 | 1000 | 1600 | 2000 | 2500 | 4000 | 5000 |
- Overload pressure | p [bar] | 750 | 840 | 1200 | 2400 | 2400 | 2600 | 4800 | 6000 |
- Burst pressure | p [bar] | 1000 | 1050 | 1500 | 3000 | 3000 | 4500 | 6000 | 7000 |
ELECTRICAL PARAMETER | ||||||
---|---|---|---|---|---|---|
2-wire | 3-wire | 3-wire | 3-wire | 3-wire | ||
Output signal* | 4...20mA | 0...20mA | 0...10V | 0...5V | 0,5...4,5V ratiometric | |
Supply voltage | US[VDC] | 10...32** | 9...30 | 12...32 | 8...32 | 5±10% |
Load resistor | RA in Ω | RA=(US-10V)/0,02A |
max. 200Ω** | ≥4.7kΩ | ≥4.7kΩ | ≥4.7kΩ |
Response time | t [ms] | ≤ 2 | ≤ 1 | ≤ 1 | ≤ 1 | ≤ 1 |
Maximum supply current | I [mA] | 23 | 40 | 10 | 10 | 7,5 |
Isolation voltage | U [VDC] | 50 | **>AppNote (see www.adz.de) |
ACCURACY | |||||
---|---|---|---|---|---|
ACCURACY @RT | % of the range | ≤ ,050*** | option ≤ 0,25 | *** inc;. nonlinearity, hysteresis, repeatability, zero-offset and final-offset (acc. to IEC 61298-2) |
|
Non-linearity | BFSL | ≤ 0,15 | |||
Stability/year | % of the range | ≤ 0,15 |
ACCEPTABLE TEMPERATURE RANGE**** | **** customized configurations possible | |||||
---|---|---|---|---|---|---|
Measuring medium, alwats | T[°C] | -40...160 | ||||
Measuring medium, up to 15 min | T[°C] | -40...180 | ||||
Ambience | T[°C] | -40...105 | ||||
Storage | T[°C] | -40...125 | ||||
Compensated range***** | T[°C] | -20...85 | ***** The mean TC are relevent for the compensated only, outside the compensated range the total error statements apply. |
|||
Mean TC offset | % of the range | ≤ 0,15/10K | ||||
Mean TC offset | % of the range | ≤ 0,15/10K | ||||
Total error | % of the range | -40°C 2,00% | ||||
% of the range | 105°C 2,00% | |||||
% of the range | 160°C 3,00% |
MECHANICAL PARAMETER | ||||||
---|---|---|---|---|---|---|
Wetted cpmponents | stainless, titaniun | |||||
Housing | stainless, titaniun | |||||
Weight | m [g] | ~250 | depending on design | |||
Shock resistance/drop | g | 1000 | acc. to DIN EN 60068-2-32-free fall | |||
Vibration resistance | g | 20 | acc. to DIN EN 60068-2-6 vibration sinusoidal | |||
Shock resistance/constant | g | 50 | acc. to DIN EN 60068-2-27-shock | |||
Approvals | CE Declarations of conformity 2014/30/EU, 2014/68/EU; Railway application DIN EN 50155 | |||||
IP system of protection (IEC 605029) up to IP69K | The IP system of protection as specified in the data sheets generally applies, with appropriate mating connected. |