นาฬิกาตั้งเวลาแบบดิจิตอล
Digital Timer Switch รุ่น H5S Series
คุณลักษณะ
Easier, More Convenient Time Switchies, with New 4-circuit Output and Yearly Models in additon to 2- circuit Weekly Models
- Independent Day Keys provide easier operation.
- Temporary holiday function makes it easy to tuen OFF output for holidays and non-operating days.
- Setting can be made even with the Time Switch turned OFF.
- Test mode enables easy program checking.
- Conplies with EMC Directives, UL/CSA, and other safety standards.
- Includes summer time (DST) adjustment. Yearly models also offer autoamtic switching to DST.
- Set value can be changed both upward and downward for speedier setting.
- Integrated temperature compensation circuit helps keep accurate time over a wide temperature range. *1
- Includes time counter and total counter function with alarm indicator. *2
- Bank function allows program switching by an external input. *3
- New 4-circuit output models with a compact, 72 x 72 mm DIN size added to the series.
- Available only on yearly models.
- Availalbe only on 2-circuit models.
- Available only on weekly models.
คุณสมบัติ
MODEL | Weekly 2-circuit Models (H5S-W[]2) | Yearly 2-circuit Models (H5S-Y[]2) | Yearly 4-circuit Models (H5S-Y[]4) | ||
---|---|---|---|---|---|
Rated supply voltage | 100-240VAC 50/60Hz, 24VDC *1 | ||||
Operating voltage range | AC: 85-110% rated supply voltage DC: 85-120% rated supply voltage |
||||
Power consumption | Approx 2.9VA at 264VAC 60Hz Approx 0.8W at 28.8VDC |
Approx 3.2VA at 264VAC 60Hz Approx 0.9W at 28.8VDC |
Approx 3.5VA at 264VAC 60Hz Approx 1.0W at 28.8VDC |
||
Control outputs | Number of circuits | SPST-NO x 2 circuits | SPST-NO x 4 circuits | ||
Circuits | Power supply circuit and other (no-voltage) circuit | ||||
Capacity | Resistive load (cosϕ = 0.7) |
15A at 250VAC *2 | 3A at 250VAC | ||
Inductive load | 10A at 250VAC (cosϕ = 0.7) | 2A at 250VAC (cosϕ = 0.4) | |||
Ambient operating temperature | -10 to 55°C (with on icing or condensation) | ||||
Ambient operating humidity | 25 to 85% | ||||
Storage temperature | -25 to 65°C (with on icing or condensation) | ||||
Case color | Light gray (Munsell 5Y7/1) |
- Do not use inverter output as a power supply. For details, refer to Precautions for Safe Use, item 24, on Data sheet.
- The capacity is 15A/circuit, but derating of total current for two circuits is required.
Characterisics
MODEL | Weekly 2-circuit Models (H5S-W[]2) | Yearly 2-circuit Models (H5s-Y[]2) | Yearly 4-circuit Models (H5S-Y[]4) | |
---|---|---|---|---|
Accuracy of operating time | ± 0.01% ±0.05s max *1 The ± 0.01% value applies to the set time interval. |
|||
Setting error | ||||
Influence of voltage | ||||
Influence of temperature | ||||
Cyclic error | ± 15s/month | ±15 s/month (at -10°C to 45°C), ± 20s/month (at 45 to 55°C) | ||
Memory protection |
Continuous use: 5 years min (at 25°C) *2 | |||
Insulation resistance | 100MΩ min. (between current-carrying terminals and exposed non-current carrying metal parts, between operation circuit and control output circuit and control output circuits, and between non-continuous contacts.) | |||
Dielectric strength | 2,950VAC 50/60Hz for 1min (between current-carrying terminals and exposed non-current carrying netal parts) 2,000VAC 50/60Hz for 1min (between operation circuit and control output circuit, and between control output circuits) 1,000VAC 50/60Hz for 1min (between non-continuous contacts) |
|||
Noise immunity | ±1,500V (between power terminals, for AC power models), ±500V (between power terminals, for DC power models) Square-wave noise by noise simulator (pulse width: 100ns, for 1µs, 1-ns rise time) |
|||
Vibration resistance | Destruction | 10-55Hz with 0.375mm single amplitude in 3 directions for 2 hours each | ||
Malfunction | 10-55Hz with 0.25mm single amplitude in 3 diractions for 10 minutes each | |||
Shock reisistance | Destruction | 300 m/s2 3 times each in x, y, and z axes, 6 directions | ||
Malfunction | 100 m/s2 3 times each in x, y, and z axes, 6 directions | |||
Life expectancy | Mechanical | 100,000 operations min. | ||
Electrical | 50,000 operations min (15A at 250VAC, resistive load) 50,000 operations min (10A at 30VDC, resistive load) 50,000 operations min (10A at 250VAC, inductive load (cosϕ = 0.7)) 50,000 operations min (1 HP at 250VAC, motor load) 50,000 operations min (100W at 100VAC, lamp load) 10,000 operations min (300W at 100VAC, lamp load) |
50,000 operations min. (3A at 250VAC, resistive load) 50,000 operations min. (3A at 30VDC, resistive load) |
||
Approved standards | cURus: UL508/CSA C22.2 No.14 Conform to EN 60730-2-7(Pollution degree 2/overvoltage category ll) Conform to VDE 0106/part100. Conform to Electrical Appliance and Material Safely Law (for Japan) |
|||
EMC | (EMI) EN 60730-2-7 EMI Radiated: EN 60730-2-7 (CISPR 22 Class B) EMI Conducted (continouus): EN 60730-2-7 (CISPR 22 Class B) EMI Conducted (Non-continuous): EN 60730-2-7 (CISPR 14-1) Harmonic Current: EN 60730-2-7 (IEC 61000-3-2 Class A) Voltage fluctuation/flicker: EN 60730-2-7 (IEC 61000-3-3) (EMS) EN 60730-2-7 ESD Immnity: EN 60730-2-7 (IEC 61000-4-2): 6kV cpntact discharge, 8kV air discarge Radiated electromagnetic Field Immunity: EN 60730-2-7 (IEC 61000-4-3): 10-V/m AM modulation (80 MHz to GHz, 1.4GHz to 2GHz), 10-V/m pulse modulation (900 MHz) Conducted Disturbance Immunity: EN 60730-2-7 (IEC 61000-4-6): 10V (0.15 to 80MHz) Burst Immunity: EN 60730-2-7 (IEC 61000-4-4): 1kV line to line (power line, output line), 2kV line to ground (power line, Ouput line), 0.5 kV to line (input line), 1kV line to ground (input line) Voltage Dip/Interrupting Immunity: EN 60730-2-7 (IEC 61000-4-11): 0.5s cycle, 100% (rated voltage) |
|||
Weight | Approx 200g |
- The total error including the repeat accuracy, setting error, variation due to voltage change, and variation due to temperature change is ±0.01% ±0.05s max.
- The time given for memory protection is the calculated time of when power is not neing supplied (inckuding during storage) at an ambient temperature of 25°C. The timer functions and set program are backed up by a lithium battery that is built into the Time Switch. These will be lost if the life of the battery expires, if the lithium battery is replaces (if the PCB is repalced), the stored contents will also be lost.
Operation
MODEL |
Weekly 2-circuit | Yearly 2-circuit Models (H5S-Y[]2) | Yearly 4-circuit Models (H5S-y[]4) | |
---|---|---|---|---|
Operation method | Digital quartz | |||
Operation period | 1 week(7 days) | 1 year (with integrated calendar to 2099) | ||
Display | Day, hrs (switchable between 24-hr indication and a.m./p.m 12-hr indication), minutes, seconds (0.00 to 23.59, 0.00 to 11.59 a.m., 0.00 to 11.59 p.m.) Digital indication by LCD (charactor height: 10mm) Digital display of operation schedule during operation Timing chart display of operation schedule during operation |
|||
Min. setting unit | 1 min | |||
Number of steps that can be set | Weekly program *1 | 40 steps/circuit | 48 steps/circuit *2 24 steps/circuit (per season) *3 |
48 steps/circuit *2 12 steps/circuit (per season) *3 |
Yearly program | --- | 4 yearly programs/circuit | ||
Number of settable yearly temporary holiday settings | --- | 16 |
- Depending the operation, the following steps can be used for weekly program.
Timer operation: 2 steps
Pulse-output operation: 1 step
Cyclic operation: 4 steps - When the season switching setting is not being used.
- When the season switching setting is being used.
Operation Functions
MODEL |
Weekly 2-circuit | Yearly 2-circuit Models (H5S-Y[]2) | Yearly 4-circuit Models (H5S-y[]4) | |
---|---|---|---|---|
Weekly timer operation | Controls the output according to the set time of ON and OFF. Min setting unit: 1min Multiple-day operation also possible. |
|||
Weekly pulse-output operation | Outpu turns ON for a fixed period (pulse width) at the set ON time. Pulse width: 1 to 59s (in 1s increments), or 1 to 60min (in 1min increments) The pulse width can be set for each step. |
|||
Weekly cyclic operation | Repaetedly turns ON and ODFF during the period from the cyclic start time to tje stop time. Independent ON- and OFF-time settings are possible. Min. setting unit: 1min (The ON time width and OFF the width can each be set to between 1 minute and 11 hours 59 minutes) (The timer operation rapeatedly turns the signal ON and OFF for the time widtg specified by the ON time and OFF time during the period from the day of the week and time that are set for the cyclic start time to the day of the week and time that are set for the stop time.) |
|||
Yearly timer operation | --- | Adds a yearly timer operation to the weekly timer program. For details, refer to About Yearly Programs on Data Sheet. |
||
Yearly pulse-output operation | --- | Adds a yearly pulse-output operation to the weekly pulse-output program. For details, refer to About Yearly Programs on Data Sheet. |
||
Temporary holiday setting |
Stes temporary holidays (non-operating days) without having to revise the existing program. |
|||
Day override operation | Executes the operation for one day temporarily on another day in the 7-day period starting from the current day. For details, refer to Day Override Operation on Data Sheet. |
--- | ||
Program check | Consecutively displays the days and times when the output is set to turn ON and OFF for one over the coure of one week in the sequence in which the Time Switch is to operate. For details, refer to Program check Function on Data Sheet. |
|||
Checking the settings | Consecutively displays the days and times whem the output is set turn ON and OFF over the course of one week in the sequence in which the Time Swtich is to operate. For details, refer to checking the Setting on Data Sheet. |
|||
Forced ON/OFF operation | Allows the output to be forcibly turned ON/OFF by the Output NO/OFF Switch regardless of the control output setting | |||
Override and automatic return operation | Allwos the contrl output to ebe maintained in the ON (or OFF) state until the nect OFF (or ON) time. Thos operation is controlled by using the Output ON/OFF Switch and write key. When completed, the Time Switch automatically resumes the previously set operation. For details, refer to Override and Automatic Return Operation on Data Sheet. |
|||
Summertime (DST) adjustment | Switches the current time from "Current time" to "cunrrent time +1h" for daylight savings time. Yearly models also offer automatic switching to daylight saving time. For details, refer to manual Summer Time (DST) Adjustment on Data Sheet. |
|||
Time counter/total counter display |
Display the total elapsed time and total count of external input. It also displays a warning when a set value is entered. For details, refer to Time Counter/Total Counter Display (F2, F3, F4) on Data sheet | --- | ||
Time adjustment input | Allows the time to be set to 00min 00s at the same time as an external input is applied. For details, refer to Time Adjustment Input Function (F2) on Data Sheet. |
--- | ||
Manual operation on recovery from power failure | Allows the output state to be specified following recovery from a power failure. For details, refer to Manual Operationn in Recovery from Power Failure (F2) on Data sheet |
--- | ||
Bank switching | Allows two groups (banks) of programs to be registered and switched by external input. For details, refer to Bank Switching (F2) on Data Sheet. | --- | ||
Season switching | --- | Allows weekly program to be automatically switched in response to seasons throughout the year. For details, refer to Season Switching/Period of Season (F8/F9) on Data Sheet. |
||
Power OFF settings | Allows the display to remain lit even when the power is turned OFF, and settings to be made for all functions except Override and Automatic Return Operation. The display illumination will turn OFF when there has no operation for 2 min. The display will light agian when any key other than a slide switch is pressed for at least 1s. No output will be generated. |