เครื่องตั้งเวลาแบบดิจิตอล DIGITAL TIMER
รุ่น H5CX
คุณลักษณะ
เป็นเครื่องตั้งเวลาแบบดิจิตอล
- ช่วงการวัด : 9.999 S – 999.9 Hr
- ไฟเลี้ยง : 100 - 240 Vac
- เอาท์พุต SDPT 250 VAC 3A
คุณสมบัติ
MODELS | H5CX-A-[]-N | H5CX-A11[]-N | H5CX-L8[]-N | ||
---|---|---|---|---|---|
Classification | Standard Type | Economy Type | |||
Ratings | Power supply voltage *1 | 100-240VAC 50/60Hz | |||
Operating voltage fluence range | 85-110% of rated supply voltage (90-110% at 12-24VDC) | ||||
Power consumption | Approx 6.2VA at 100-240VAC, Approx 5.1VA/2.4W at 24VAC/12-24VDC *2 | ||||
Mounting method | Flush mounting | Flush mountin, surface mouting, DIN track mounting | |||
External connections | Screw terminals | 11-pin socket | 8-pin socket | ||
Degree of protection | IEC IP66, UL508 Type 4X (indoor) for panel surface only and when Y92S-29 Waterproof Packing is uesd | ||||
Digits | 4 digits | ||||
Timer ranges |
0.001-9.999s, 0.01-99.99s, 0.1-999.9s, 1-9999s, 1s - 99min 59s, 0.1m-999.9min, 1-9999min, 1min - 99h 59min, 0.1-999.9h, 1-9999h |
||||
Timer mode | Elapsed time (Up), remaining time (Down) (Selectable) | ||||
Inputs | Input signals | Signal, Reste, Gate | Signal, Reset(no inputs on models with instantaneous contact outputs) | ||
Input method | No-voltage Input: ON impedance: 1kΩ max.(Leakage current 12mA when 0Ω) ON residual voltage: 3V max OFF impedance: 100kΩ min. Voltage Input High (logic) level: 4.5-30VDC Low (logic) level: 0-2VDC (input resistance: approx 4.7kΩ) No-voltage input/voltage input (switchable) |
No-voltage Input ON impedance :1kΩ max (Leakage current: 12mA when 0Ω) ON resudual voltage: 3V max. OFF impedance: 100kΩ min. |
|||
Signal, reset, gate | Minimum input signal width: 1 or 20ms (selectable, same for all input) | ||||
Reset system | Power reset (depending on output mode), external reset, manual reset, automatic reset (depending on output mode) | ||||
Power reset | Minimum power-opening time: 0.5s (except for A-3, b-1, F, ton-1, and toff-1 mode) | ||||
Reset voltage | 10% max. of rated supply voltage | ||||
Sensor waiting time | 250 ms max. (Control output is turnned OFF and no input is accepted during sensor waiting time.) | ||||
Outputs | Output modes | A: Signal ON Delay l, A-1: Signal ON Delay ll, A-2: Power ON Delay l, A-3: Power ON Delay ll, b: Repeat Cycle 1, b-1: Repeat Cycle 2, d: Signal OFF Delay, E: Interval, F: Cumulatative, Z: ON/OFF-duty-adjustable flicker, S: Stopwatch, toff: Flicker OFF Start 1, ton: Flicker ON Start 1, toff-1: Flicker OFF Start 2, ton-1: Flicker ON Start 2 | Models with Instantaneous Contact Outputs A-2: Power ON Delay l, b: Repeat Cycle 1, E: Interval, Z: ON/OFF-duty-adjustable flicker, toff: Flicker OFF Start 1, ton: Flicker ON Start 1 | ||
One-shot output time | 0.01 - 99.99 s. | ||||
Control output | Models with Contact Outputs 5A at 250VAC/30VDC, resistive load (cos = 1) Minimumapplied load: 10 mA at 5VDC (failure level: P, reference value) Contact materials: AgSnln Contact Output: NPN open collector, 100mA at 30VDC max. residual voltage: 1.5VDC max. (Approx 1V), Leakage current: 0.1mA max. |
||||
Display method *3 | 7-segment, negative transmissive LCD; Present value: 12-mm-high charaters, (switchable between red, green, and orange) Set value: 6mm high characters, green |
7-segment, neative transmissive LCD; Present value: 12mm high charaters, green |
|||
Memory backup | EEPROM (overweites: 100,000 times min.) that can store data for 10 years min. | ||||
Operating temperature tange | -10 to 55℃ (-10 to 50℃ if counters are mounted side by side) (with no icing or condensation) | ||||
Storage temperature range | -25 to 70℃ (with no icing or condensation) | ||||
Operating humidity tange | 25-85% | ||||
Case color | Black (N1.5) (Optional Front Panels are available to charge the Front Panel color to light gray or white.) | ||||
Attachments | Waterproof packing, flush mounting adapter, label for DIP switch settings | Label for DIP switch setting | --- |
- Do not use the output from an inverter as the power supply. The ripple must be 20% Maximum for DC power.
- Inrush current will flow for a short time when the power supply is tured ON. Inrush Cureent (Reference Values)
- The Display is lit only when the power is ON. Nothing is displayed when power is OFF.
Voltage | Applied voltage | Inrush current (peak value) | Time |
---|---|---|---|
100-240VAC | 264VAC | 5.3A | 0.4ms |
12-24VDC/24VAC | 26.4VAC | 6.4A | 1.4ms |
26.4VDC | 4.4A | 1.7ms |
Characteristics
Accuracy of operating time and setting error (Including temperature and voltage influences) |
Power-ON start:±0.01%±50ms max. (See note 1.) Signal start:±0.005%±30ms max. (See note 1.) Signal start for transistor output model:±0.005%±3ms max. (See note 1&2) If the set value us within the sensor waiting time at startup the control output of the H5CX will not turn ON untill the sensor waiting time passes. Note: 1. The values are based on the set value. 2. The value is applied for a minimum pulse width of 1 ms. |
|
Insulation resistance | 100MΩ min. (at 500VDC) between current-carrying terminal and exposed non-current-carrying meatl parts, and between non-continuous contacts | |
Dielectric strength | 2,000VAC 50/60Hz for 1 min between current-carrying metal parts and non-current-carrying metal parts 2,000VAC 50/60Hz for 1 min between power supply and input circuits for the models other than H5CX-[]D-N 1,000VAC 50/60Hz for 1 min between control output, power supply and input circuits for H5CX-[]SD-N 2,000VAC 50/60Hz for 1 min between control output, power and input circuits for other models 1,000VAC 50/60 Hz for 1 min between non-continuous contacts |
|
Impulse withstand voltage | 5kV (between power terminals) for 100-240VAC, 1kV for 24VAC/12-24VDC 5kV (between current-carrying terminal and exposed non-current-carrying metal parts) for 100-240VAC 1.5kV for 24VAC/12-24VDC |
|
Noise immunity | ±1.5kV (between power terminals) and ±600V (between input terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise) | |
Static immunity | Malfunction : 8kV Destruction : 15kV |
|
Vibration resistance | Destruction | 10-55Hz with 0.75mm single amplitude each in three directions for 2 h each |
Malfunction | 10-55Hz with 0.35mm single amplitude each in therr directions for 10 min each | |
Shock resistance | Destruction | 300 m/s2 in three directions, three cycles |
Malfunction | 100 m/s2 in three directions, three cycles | |
Life expectency | Mechanical | 10,000,000 operations min. (under on load at 1,800 operations/h and ambient temperature of 23℃) |
Electrical | 100,000 operations min. (5A at 250VAC, resistive load at 1,800 operations/h and ambient temperature of 23℃) * | |
Weight | Approx 115g (Timer only) |
*Refer to Life-test Curve.
Approved safety standards | UL508/Listing, UL508 Type 4X for indoor use (enclosure rating), CSA C22.2 No.14 *1, conforms to EN61812-1 (Pollution degree 2/overvoltage category lll) B300 PILOT DUTY 1/4 HP 120VAC, 1/3 HP, 240VAC, 5A resistive load VDE0106/P100 CCC: GB/T 14048.5 Pollution degree 2, Overvoltage category lll *2, *3 |
EMC | (EMI) EN61812-1 Emission ENclosure: EN55011 Group 1 class A Emission AC main: EN55011 Group 1class A (EMS) EN61812-1 Immunity ESD: IEC61000-4-2 Immunity RF-interference: IEC61000-4-3 Immunity Burst: IEC61000-4-4 Immunity Surge: IEC61000-4-5 Immunity Conducted Disturbance: IEC61000-4-6 Immunity Voltage Dip/Interruption: IEC61000-4-11 |
- The following safety standards apply to models with sockets (H5CX-A11[] or H5CX-L8[]).
cUL (Listing): Applicable when any other socket is used.
cUR (Recognition): Applicable when any other socket used. - Excluding the H5CX-ASD-N/-A11SD-N/-L8SD-N.
- CCC certification requirements
Rated operating voltage Ue Rated operating current Ie |
Contact Output: AC-15: Ue: 250VAC, Ie: 3A AC-13: Ue: 250VAC, Ie: 5A DC-13: Ue: 30VDC, Ie: 0.5A Transistor Output DC-13: Ue: 30VDC, Ie: 0.1A |
Rated insulation voltage | 250V |
Rated inpulse withstand voltage (altitude: 2,000m max.) |
4kV (at 240VAC) |
Conditional short-circuit current | 1000A |
I/O Functions
For details, refer to the timing charts on Data Sheet.
Inputs *1 | Start signal | Nornally functions to start timing. Inmodes A-2 and A-3, disable timing. In mode S, starts and stops timing. | |
Reset | Resets present value. (In elapsed time mode, the present value returns to 0; in remaining time mode, the present value returns to the set value.) Count inputs are not accepted and control output turn OFF while reset input is ON. Reset indicator is lit while reset input is ON. |
||
Gate *2 | Disables timing. (If reset occurs while the gate input in ON, a reset will be performed.) | ||
Outputs | Control output(OUT) | Outputs take place according to designa ted operating mode when reaches corresponding set value. |
- The H5CX-L8[] does not have an input.
- The H5CX-L[] does not have a gate input.
Response Delay Time When Resetting (Transistor Output)
The Following table shows the delay from when the reset signal is input untill the output is turned OFF. (Reference value)
Minimum reset signal width | Output delay time |
---|---|
1 ms | 0.8-1.2 ms |
20 ms | 15-25 ms |
H5CX-B[]-N
Ratings
Classification | Digitak Timer with 6-digit display, 2-stage setting, and forecast output | ||||
Ratings | Power supply voltage | 12-24VDC | |||
Operating voltage fluence range | 90-110% of rated supply voltage | ||||
Power consumption | Approx 2.3W *1 | ||||
Mounting method | Flush mounting | ||||
External connections | Screw terminals | ||||
Degree of protection | IEC IP66, UL508 Type 4X (indoors) for panel front surafce only and only when Y92S-29 Waterproof Packing is used | ||||
Digits | 6 digits | ||||
Timer ranges |
0.01-9999.99 s, 1s - 99h 59min 59s, 0.1 - 99999.9 min, 0.1 - 99999.9h |
||||
Timer mode | Elapsed time (Up) | ||||
Inputs | Input signals | Signal, Reste, Gate | |||
Input method | No-voltage Input: ON impedance: 1kΩ max.(Leakage current 12mA when 0Ω) ON residual voltage: 3V max OFF impedance: 100kΩ min. Voltage Input High (logic) level: 4.5-30VDC Low (logic) level: 0-2VDC (input resistance: approx 4.7kΩ) No-voltage (NPN) input/voltage (PNP) input (switchable) |
||||
Signal, reset, gate | Minimum input signal width: 1 or 20ms (selectable, same for all input) | ||||
Reset system | Power resets (only dor A mode), external and manual reset | ||||
Power reset | Minimum power-opening time: 0.5s (except for F-1 mode) | ||||
Reset voltage | 10% max. of rated supply voltage | ||||
Sensor waiting time | 250 ms max. (Control output is turnned OFF and no input is accepted during sensor waiting time.) | ||||
Outputs | Output modes | A, F-1 | |||
Output type | Transistor output: NPN open collector, 100mA at 30VDC max. residual voltage: 1.5VDC max (Approx 1V) Leakage current: 0.1mA max | ||||
Display | 7-segment, negative transmissive LCD; Present value: 10-mm-high charaters, red Set value: 6mm high characters, green *2 |
||||
Memory backup | EEPROM (overweites: 100,000 times min.) that can store data for 10 years min. | ||||
Operating temperature tange | -10 to 55℃ (-10 to 50℃ if counters are mounted side by side) (with no icing or condensation) | ||||
Storage temperature range | -25 to 70℃ (with no icing or condensation) | ||||
Operating humidity tange | 25-85% | ||||
Case color | Black (N1.5) | ||||
Attachments | Waterproof packing, flush mounting adapter, unit label |
- Inrush current will flow for a short time when the power supply is turned ON. Inrush Current (Reference Values)
- The display is lit only when the power is ON.
Voltage | Applied voltage | Inrush current (peak value) | Time |
---|---|---|---|
12-24VDC | 26.4VDC | 4.4A | 1.7ms |
characteristics
Accuracy of operating time and setting error (Including temperature and voltage influences) |
Power-ON start:±0.01%±50ms max. (see note 1) Signal start: ±0.005%±0.03ms max. (see note 1) Signal start for transistor output model: ±0.005%±3ms max. (see note 1&2) If the set value is within th sensor waiting time at startup control output of the H5CX will not turn ON untill the sensor waiting time passes Note: 1 The values are based on the set value. 2 The value is applied for a minimum pulse width of 1ms. |
|
Insulation resistance | 100MΩ min. (at 500VDC) between current-carrying terminal and exposed non-current-carrying metal parts | |
Dielectric strength | 2,000VAC 50/60Hz for 1 min between current-carrying metal parts and non-current-carrying metal parts 1,000VAC 50/60Hz for 1 min between control output, power supply, and input circuit |
|
Impulse withstand voltage | 1.0kV (between power terminals) 1.5kV (between current-carrying terminal and exposed non-current-carrying metal parts) |
|
Noise immunity | ±480V (between power terminals) and±600V (between input terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 μs, 1-ns rise) | |
Static immunity | Destruction: 15kV Malfunction: 8kV |
|
Vibration resistance | Destruction | 10-55Hz with 0.75mm single amplitude in three directions for 2 h each |
Malfunction | 10-55hZ with 0.35mm single amplitude in three directions for 10 min each | |
Shock resistance | Destruction | 300 m/s2 in three directions, three cycles |
Malfunction | 100 m/s2 in three directions, three cycles | |
Weight | Approx 105g (Timer only) |
Approved safety standards | UL508/Listing, CSA C22.2 No.14, conform to EN61812-1 (pollution degree 2/overvoltage category lll) Conforms to VDE0106/P100 (finger protection) |
EMC | (EMI) EN61812-1 Emission Enclosure: EN55011 Gruop 1 class A (EMS) EN61812-1 Immunity ESD: IEC61000-4-2 Immunity RF-interference: IEC61000-4-3 Immunity Burst: IEC61000-4-4 Immunity Surge: IEC61000-4-5 Immunity Conducted Disturbance: IEC61000-4-6 Immunity Voltage Dip/Interruption: IEC61000-4-11 |
I/O Functions
Inputs | Start signal | Starts timing | |
Reset | Reset present value. (The present value returns to 0) Timing stops and control output turns OFF while reset input is ON. Reset indicator is lit while reset input is ON. |
||
Gate | Inhibits timer operation. | ||
Outputs | Forecast value setting | Control output (OUT2) | Turn ON when the present value reaches the set value. |
Forecast output (OUT1) | Turn ON when the present value reaches the forecast value. | ||
Absolute value setting | Control output 2 (OUT2) | Turn ON when the present value reaches set value 2 | |
Control output 1 (OUT1) | Turn ON when the present value reaches set value 1 |
Response Delay Time When Resetting (Transistor Output)
The following table shows the delay from when signal is input until the output is turned OFF. (Reference value)
Minimum reset signal width | Output delay time |
---|---|
1ms | 0.8-1.2ms |
20ms | 15-25ms |