เครื่องตั้งเวลาแบบอนาล็อค Analog Timer
รุ่น H3Y
คุณลักษณะ
เป็นเครื่องตั้งเวลาแบบอะนาล็อค แบบเข็มหมุนได้
- Power On Delay
- ช่วงการ : 1, 5, 10, 30, 60 S, 3, 5, 10, 30, 60 M
- ไฟเลี้ยง 12 Vdc, 24 Vdc, 110 Vac, 220 Vac
- เอาท์พุต DPDT 250 VAC 5A / 4DPT 250 VAC 5A
- ใช้ซ็อคเก็ต H3Y - 2 PF083A - E, H3Y - 4 PYF - 14A - E
- Semi-multi power supply voltage
- Large transparent time setting knob facilitates time setting. A flat-blade and Philips screwdriver can also be used for time setting.
- Pin configuration compatible with MY Power Relay
- LED indication for power and output statuses
- Conforms to EMC standards.
- Conforms to EN 61812-1 and approved by UL and CSA
คุณสมบัติ
Time Range
Rated time | Time setting range | Rated time | Time setting range |
---|---|---|---|
0.5s | 0.04-0.5s | 3 min | 0.1-3 min |
1s | 0.1-1s | 5 min | 0.2-5 min |
5s | 0.2-5s | 10 min | 0.5-10 min |
10s | 0.5-10s | 30 min | 1-30 min |
30s | 1.0-30s | 60 min | 2-60 min |
60s | 2.0-60s | 3 h | 0.1-3 h |
120s | 5.0-120s | --- | --- |
Characteristics
MODEL | H3Y-2(-0)/H3Y-4(-0) |
Rated supply voltage | 100-120 50/60Hz, 200-230VAC 50/60Hz, 24VAC 50/60Hz *1 12, 24, 48, 125, 100-110VDC *2,*3 |
- Do not use the output from an inverter as the power supply. Refer to Safety Precautions for All Timer for details on your OMRON website.
- With DC ratings, single-phase full-wave rectified power sources may may be used.
- Onlythe H3Y-2 and H3Y-2-0 Series include 12VDC models.
- Use the Timer within 90-110% of the rated supply voltage (95-100% for 12VDC) when using it continuously under an ambient operating temperature of 50℃
- Set the reset voltage as follows to ensure proper resetting
- 100-120VAC : 10VAC max.
- 200-230VAC : 20VAC max.
- 100-110VDC : 10VDC max.
- Refer to Safety Percautions for All Timer in your OMRON website when combining the Timer with an AC 2-wire proximity sensor.
- A diode to prevent reverse voltage is provided only on models with a DC power supply.
Characteristics
Accuracy of operating time | ±1% FS max. (0.5s tange : ±1%±10 ms max.)*1 |
Setting error | ±10%±50 ms FS max. |
Reset time | Min. power-opening time : 0.1s max. (including halfway reset) |
Influence of voltage | ±2% FS max. *1 |
Influence of temperature | ±2% FS max. *1 |
Insulation resistance | 100mΩ min. (at 500VDC) |
Dielectric strength |
2,00VAC 50/60Hz for 1min (between current-carrying terminals and exposed non-current-carrying metal parts) *2 |
Impulse withstand voltage | Between power terminals 3kV for 100-120VAC, 200-230VAC, 100-110VDC, 125VDC 1kV for 12VDC, 24VDC, 48VDC Between exposed non-current-carrying metal parts 4.5kV for 100-120VAC, 200-230VAC, 100-110VDC, 125VDC 1.5kV for 12VDC, 24VDC, 48VDC |
Noise immunity | ±1.5kV, square-wave noise by noise simulator (pulse width : 100 ns/1 µs, 1-ns rise) |
Static immunity | Destruction : 8kV Malfunction : 4kV |
Vibration resistance | Destruction : 10-55Hz 0.75mm single amplitude Malfunction : 10-55Hz 0.5mm single amplitude |
Shock resistance | Destruction : 1,000 m/s2 (approx 100G) *3 Malfunction : 100 m/s2 (approx 10G) |
Life expectancy | Mechanical : 10,000,000 operations min. (under no load at 1,800 operatings/h) Electrical : H3Y-2 : 500,000 operations min. (5A at 250VAC, ressitive load at 1800 operations/h) H3Y-4 : 200,000 operations min. (3A at 250VAC, resistance load at 1800 operations/h) *4 |
Enclosure rating | IP40 |
Weight | Approx 50g |
EMC | (EMI) EN 61812-1 Emission Enclosure : EN 55011 Group 1 class A Emission AC Mains : EN 55011 Group 1 class A (EMS) EN 61812-1 Immunity ESD : IEC 61000-4-2 Immunity RF-interference : IEC 61000-4-3 Immunity Burst : IEC 61000-4-4 Immunity Surge : IEC 61000-4-5 Immunity Conducted Disturbance : IEC 61000-4-6 Immunity voltage Dip/interruption : IEC 61000-4-11 |
Approved standards | UL 508, CSA C22.2 No. 14, Lloyds, CCC: GB/T 14048.5 *6 conforms to EN 61812-1 and IEC 60664-4. (2.5kV/2 for H3Y-2/-2-0, 2.5kV/1 for H3Y-4/-4-0) *5 |
- Add±10 ms to the above value for the 0.5-S range model.
- Terminal screw sections are excluded.
- The destructive shock resistance test was performed on the Timer.
- Check the electrical life curve.
- Overvoltage category ll.
- CCC certification requirements.
MODEL | H3Y-2(-0) | H3Y-4(-0) |
---|---|---|
Recommended fuse | RT14-20/6A (380VAC 6A),Manufactured ny DELIXI | RT14-20/4A (380VAC 4A), manufactured ny DELIXI |
Rated operating voltage Ue Rated Operating current le |
AC-15 : Ue : 250VAC, Ie : 3A AC-13 : Ue : 250VAC, Ie : 5A DC-13 : Ue : 30VDC, Ie : 0.5A |
AC-15 : Ue : 250VAC, Ie : 2A AC-13 : Ue : 250VAC, Ie : 3A DC-13 : Ue : 30VDC, Ie : 0.5A |
Rated insulation voltage | 250V | |
Rated inpulse wuthstand voltage (alitutude : 2,000m max.) | 2.5kV (at 240VAC) | |
Conditional short-circiut current | 1000A |