เครื่องนับจำนวนแบบดิจิตอล Digital Counter
รุ่น 54U Series
คุณลักษณะ
The Codix 54U is a voltage-powered dual function counter with 4 functions in one device: Counter with 2 totalizing ranges, totalizer and timer, totalizer and frequency meter, timer with 2 time ranges. For fast and slow count pulses, with 6-digit LED display for NPN, PNP input signals.
- Fast count and frequency input – input frequency max. 60 kHz (can be damped to 30 Hz for mechanical contacts).
- Robust housing – IP65 protected.
- Very bright LED display, 14 mm high, 6 digits.
- Very accurate precise frequency measurement principle (HRA-High Rate Accuracy System) Frequencies up to 38 Hz are calculated using time-interval (period duration) measurement. Frequencies > 38 Hz are calculated using a special time base (gate time) measurement. A very high accuracy of < 0.1 % is achieved, even with very short gate times. The resulting measurement is available after a max. of 50 ms.
- Short start-up time – detects input pulses just 16 msec after being switched on => no pulses are lost with a simultaneous motor start-up.
- Large keys – can also be operated when wearing gloves.
- Programming
- Simple uniform menu-driven programming and operation.
- Possible to enter the programming also during operation with a confirmation prompt.
- Pressing the right key switches between displays.
- Individually programmable scaling: multiplication and division factor (0.0001…99.9999), to display corresponding engineering units, e.g. position in 1/10 mm and speed in RPM.
- Separate factors for frequency- and pulse counting.
- AC or DC power supply.
- Inputs : as an alternative to the HTL inputs, devices with a 5 VDC input level are available, for use as parallel displays for PLCs.
- Timer specials: timer or hours-run meter with various Start /Stop measurements, time range settings in hours, minutes or seconds, with decimal point. Resolutions up to 1/1000 can be programmed.
คุณสมบัติ
MODEL | 54U / CODIX 54U |
---|---|
Display | 6 digit, red 7 segment LED display; 14 mm (0.55“) high |
Data backup | EEPROM |
Operating temperature 10 ... 26 V DC | 20 to 65°C (-4 to 149°F) (non-condensing) |
Storage temperature | 25 to 70°C (-13 to 158°F) |
Altitude | up to 2000 m (6562‘) |
Power supply | 10 ... 30 VDC, with reverse polarity protection 100 ... 240 V AC, ±10 % |
Current consumption | max. 50 mA, 6 VA |
EMC standards | EN 55011 class B, EN 61000-6-2, EN 61000-6-3 |
Device safety : designed to | EN 61010 part 1 |
Device safety : protection class | 2 |
Device safety : application area | pollution level 2 |
UL approval | file E128604 |
Polarity of inputs | programmable, NPN or PNP for all inputs |
Input resistance | approx. 5 kΩ |
Counting frequency 1) | max. 60 kHz, can be damped to 30 Hz |
Display range | timer : 0.001 s ... 999999 h frequency meter : 1/min or 1/sec |
Minimum pulse duration of the reset input | 5 ms |
Input switching level standard version (HTL) DC power supply |
Low : 0 ... 0.2 x UB (VDC) High : 0.6 x UB ... 30 VDC |
Input switching level standard version (HTL) AC power supply |
Low : 0 ... 4 VDC High : 12 ... 30 VDC |
Input switching level at 4 ... 30 V DC | Low : 0 ... 2 VDC High : 4 ... 30 VDC |
Accuracy | frequency meter / tachometer : < 0.1 % timer : < 50 ppm |
Sensor power supply (AC version) | 24 VDC ±15 %/100 mA |