เซนเซอร์แปลงความดัน Pressure Transmitter
รุ่น PSX2
คุณลักษณะ
The explosion-proof filling level or point level sensor has excellent properties, is hermetically tight and very robust in its stainless steel housing. Appropriate protective circuits guarantee inverse-polarity protection and overvoltage resistance. The probe is of long-term stability and simple to operate
zone 0 - An area where an explosive atmosphere of a mix of air and combustible gases, vapours or sprays is permanently, over long periods or frequently prevails.
zone 1 - An area where an explosive atmosphere of a mix of combustible materials in the form of gas, vapour or spray with air occurs occasionally in normal operation.
Safety Note: When fitting, commissioning and operating this pressure transmitter, please observe relevant national safety regulations by all means.
- Measuring ranges from 0…100 mbar to 0…25 bar
- Explosion-proof certificate for zone 0 II 1G Ex ia IIB T4 Ga or II 1G Ex ia IIC T4 Ga
- Explosion-proof certificate for zone 1 II 2G Ex ia IIC T4 Gb
- Output signal 4…20 mA
- Protection class IP68
Pressure Range | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Measuring range* silicon technology | p [bar]** | 0,1 | 0,25 | 0,5 | ||||||
- Overload pressure | p [bar]** | 0,2 | 0,5 | 1,0 | ||||||
- Burst pressure | p [bar]** | 0,3 | 8,0 | 1,5 | ||||||
Measuring range* stainlees steel diaphragm | p [bar]** | 1,0 | 1,6 | 2,0 | 2,5 | 4,0 | 6,0 | |||
- Overload pressure | p [bar]** | 6 | 6 | 6 | 6 | 10 | 20 | |||
- Burst pressure | p [bar]** | 9 | 9 | 9 | 9 | 15 | 30 | |||
Measuring range* stainless steel diaphragm | p [bar]** | 10 | 16 | 20 | 25 | |||||
- Overload pressure | p [bar]** | 20 | 40 | 40 | 100 | |||||
- Burst pressure | p [bar]** | 30 | 60 | 60 | 150 | ** 1 bar is equivalent to - 10mWC | ||||
ELECTRICAL PARAMETER | ||||||||||
2-wire | ||||||||||
Output signal* | 4...20mA | |||||||||
Supply voltage | US [VDC] | 10...27V |
||||||||
Load resistor | RA [Ω] | acc. to RA = < (US–20 V)/0,02 A | ||||||||
Response time | t [ms] | ≥ 4 (digital) | ≥ 1 (analog) | |||||||
maximum supply current | I [mA] | 23 mA |
||||||||
Isolation voltage* | U [VDC] | 500V AC | ||||||||
ACCURACY | ||||||||||
pressure range of 1 bar to 25 bar | pressure range of 0,1 bar to 0,5 bar | |||||||||
Accuracy @ RT | % of the range | ≤0,50*** | Option ≤0,25 | ≤1,00*** | option ≤0,5 | |||||
Non-lineearity | BFSL | ≤0,15 | ≤0,30 | |||||||
Stability/year | % of the range | ≤0,20 | ≤0,40 | |||||||
***incl. momlinearity, hysteresis, repeatability, zero-offset and final-offset (acc. to IEC 61298-2) | ||||||||||
ACCEPTABLE TEMPERATURE RANGES | ||||||||||
Zone 0 | Zone 1 | |||||||||
Measuring medium | T [℃] | -20...60 | -40...100 | |||||||
Ambience | T [℃] | -20...60 | -40...85 | |||||||
Storage | T [℃] | -40...100 | -40...100 | |||||||
Compensated range* | T [℃] | -20...60 | -20...85 | |||||||
Mean TC Offset | % of the range | ≤ 0,15/10K | ≤ 0,15/10K | |||||||
Mean TC range | % of the range | ≤ 0,15/10K | ≤ 0,15/10K | |||||||
Total error | % of the range | -20℃ 1,00% | digital : -40℃ 1,00% | analog : -40℃ 2,00% | ||||||
% of the range | 60℃ 1,00% | digital : 85℃ 1,00% | analog : 85℃ 2,00% | |||||||
DIRECTIVE ATEX | ||||||||||
Zone 0 | Zone 1 | |||||||||
Type of ignition protection | II 1G Ex ia IIB T4 Ga | II 2G Ex ia IIC T4 Gb | ||||||||
Underlying standards | EN 60079-0, EN 60079-11, EN 60079-26, EN 60079-14 (both zones) | |||||||||
Maximum connected power | 27 V, 125mA, 0,85 W | 27 V, 125 mA, 0,85 W | ||||||||
Temperature class | T4 (Ambience -20...+60℃) | T4 (Ambience -40...+85℃) | ||||||||
MECHANICAL PARAMETER | ||||||||||
Parts in contact with the measuring medium* | stianless steel | for pressure range of 1 bar 25 bar | ||||||||
Parts in contact with the measuring medium | silicon | for pressure range of 0,1 bar 0,5 bar | ||||||||
Housing | Stainless steel | |||||||||
Casing | plastic / stainless steel | |||||||||
Cable | depending on medium (max tensile strenght 40N) | |||||||||
Shock resistance | g | 1000 | acc.to IEC 68-2-32- free fall | |||||||
Vibration resistance | g | 20 | acc.to IEC 68-2-6 and IEC 68-2-36 - vibration sinusoidal | |||||||
Mass with plastric casing | m [g] | 150 plus cable | ||||||||
Mass with steel casing | m [g] | 240 plus cable | ||||||||
Mass cable | m [g] | 40 per m | ||||||||
CE - conformity | IBExU10ATEX1014 | |||||||||
*customer specific configurations available |