เซนเซอร์แปลงความดัน Pressure Transmitter
รุ่น SME
คุณลักษณะ
The SME pressure transducer is a space saving light weight. Despite the compressed dimensions and miniaturized design the SME is robust and all stainless steel. At the same time it is full of Know-How and can be customized to individual requirements such as pressure range or output signal. The SME is not a product “off the rack”. Popular applications are motor sport and race cars. The well-known stainless steel design makes this product as robust and reliable as our standard products.
- Measuring ranges 0…1 to 0…20 bar (housing Ø ~ 14 mm)
- Measuring ranges 0…25 to 0…600 bar (housing Ø ~ 12 mm)
- Output signal 0.5…4.5 V rat., 0…5 V non-ratiometric, 4...20 mA, 0...10 V
- Media temperature range -40°C to 125°C
- In combination with temperature probe (max pressure 20 bar
- No internal transmitting media (fully welded, “dry” measuring cell)
- Round plug, ribbon cable
- Degree of protection IP67
- Highly reliable
- Miniature design - length ~ 50 mm / housing Ø ~ 14 mm / weight ~ 20 g
PRESSURE RANGE | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|
Measuring range* | ||||||||||
housing Ø ~ 14 mm | p [bar] | 1,0 | 1,6 | 2,0 | 2,5 | 4,0 | 6,0 | 10,0 | 16,0 | 20,0 |
Overload pressure | p [bar] | 6 | 6 | 6 | 6 | 10 | 20 | 20 | 40 | 40 |
Burst pressure | p [bar] | 9 | 9 | 9 | 9 | 15 | 30 | 30 | 60 | 60 |
Measuring range* | ||||||||||
housing Ø ~ 12 mm | p [bar] | 25 | 40 | 60 | 100 | 160 | 20 | 250 | 400 | 600 |
Overload pressure | p [bar] | 100 | 100 | 200 | 200 | 400 | 400 | 750 | 750 | 750 |
Burst pressure | p [bar] | 150 | 150 | 300 | 300 | 600 | 600 | 1000 | 1000 | 1000 |
(other pressure range as -1...0 bar, -1...9/24 bar etc. or absolute pressure are available) |
ELECTRICAL PARAMETER | |||||
---|---|---|---|---|---|
2-wire | 3-wire | 3-wire | 5-wire | ||
Output signal* | 4...20 mA | 0...5VDC | 0,5...4,5 V retiometric | 0,5...4,5 V retiometric | |
output signal temperature* | RT1000 | ||||
Supplt voltage | US[VDC] | 10...32** | 8...32 | 5±10% | 5±10% |
Load resistor | RA in Ω | RA =(US-10V)/0,02A | ≥4.7kΩ | ≥4.7kΩ | ≥4.7kΩ |
Response time | t [ms] | ≤ 2 | ≤ 1 | ≤ 1 | ≤ 1 |
Maximum supply voltage* | U [VDC] | 30 |
ACCURACY | |||||
---|---|---|---|---|---|
Accuracy @ RT | % of the range | ≤ 0,50*** | *** incl. nonlinearity, hysteresis, repeatability, zero-offset-and final-offset (acc. to IEC 61298-2) factor 2x accuracy for 4-20 mA output signal |
||
Non-linearity | BFSL | ≤ 0,125 | |||
Stability/year | % of the range | ≤ 0,10 |
ACCEPTABLE TEMPERATURE RANGES | ||
---|---|---|
Media | T [°C] | -40...125 |
Ambience | T [°C] | -40...85 |
Storage | T [°C] | -40...125 |
Compensated range* | T [°C] | -20...85 |
Mean TC offset | % of the range | ≤ 0,15 / 10K |
Mean TC range | % of the range | ≤ 0,15 / 10K |
% of the range | -40°C 2,00% | |
% of the range | 105°C 2,00% |
MECHANICAL PARAMETER | ||||
---|---|---|---|---|
Parts in contact with the measuring medium | stainless steel | |||
Housing | stainless steel | |||
Weight | m [g] | ~ 20 | depanding on design | |
Shock resistance/drop | g | 1000 | acc. to DIN EN 60068-2-32-free fall | |
Vibration resistance | g | 20 | acc. to DIN EN 60068-2-6-vibration (sinusoidal) | |
Shock resisrance/constant | g | 50 | acc. to DIN EN 60068-2-27-shock resistance | |
Approvals | CE Declarations conformity 2014/68/EU | |||
IP system of protection (IEC 605029) up to IP69K | IP rating applies with appropraite mating connector only. |